CloudDC SuperServer
SYS-120C-TN10R

1U CloudDC with 10 NVMe bays

Previous slide
Next slide
Intel Logo
  • Web Server, Firewall Application
  • Cloud Computing, Compact Server
  • CDN, Edge Nodes
  • Data Center Optimized, Value laaS
  • DNS & Gateway Servers, Firewall Application
  1. Dual sockets P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors
  2. Intel® C621A Chipset
  3. 16 DIMMs up to 6TB 3DS ECC DDR4-3200: LRDIMM/RDIMM/Intel® Intel® DCPMM
  4. 2 PCIe 4.0 x16 FHHL;
    2 PCIe 3.0 x2 NVMe M.2
  5. Dual AIOM (OCP 3.0) slots with NCSI for networking, 1 dedicated IPMI LAN
  6. 10x 2.5″ hot-swap hybrid NVMe/SATA/SAS drive bays
  7. 6 counter-rotating 4 cm PWM fans with optimal fan speed control, 2 air shrouds
  8. 860W redundant Platinum level 100-240Vac and 200-240 Vdc power supplies
  9. 1 VGA, 1 COM, 2 USB 3.0 (rear), 2 USB 2.0 (front)
Product SKUs
SuperServer SYS-120C-TN10R Standard version with PWS-860P-1R2 (Platinum Level)
SuperServer SYS-120C-TN10R-EU European version with PWS-861A-1R (Titanium Level)
Motherboard
Super X12DDW-A6
Processor
CPU
  • Dual Socket P4 (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 40C/80T; Up to 60MB Cache per CPU
Note
  • Supports up to 270W TDP CPUs (Air Cooled)*
  • *Air Cooled CPUs with TDP over 205W only supported under specific conditions. Contact a Tech Standard Solutions representative for details.
GPU
Max GPU Count
  • Up to 2 single-width GPU(s)
Supported GPU
  • NVIDIA PCIe: L4, A2
  • Intel PCIe: Intel Data Center GPU Flex 140
  • View GPU Options
System Memory
Memory
  • Slot Count: 16 DIMM slots
  • Max Memory (1DPC): Up to 4TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
  • Supports Intel® Optane™ persistent memory 200 series
  • View Memory Options
Memory Voltage
  • 1.2V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1/5/10 support
NVMe
  • NVMe; RAID 0/1/5/10 support(VROC HW key required)
  • View NVMe Options
Chipset
  • Intel® C621A
Network Connectivity
  • Via Slim-AIOM
  • View AIOM Options
  • View AOC Options
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated IPMI LAN port(s)
USB
  • 2 USB 3.0 port(s) (rear)
  • 2 USB 2.0 port(s) (front)
Video
  • 1 VGA port(s)
Serial
  • 1 COM port(s) (Rear)
DOM
  • 1 SuperDOM (Disk on Module) port(s)
TPM
  • 1 TPM header
System BIOS
BIOS Type
  • AMI 32MB SPI FLASH ROM
Management
Software
  • SuperCloud Composer
  • Supermicro Server Manager (SSM)
  • Supermicro Update Manager (SUM)
  • SuperDoctor® 5
  • Super Diagnostics Offline
Power configurations
  • ACPI/APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 8 Phase-switching voltage regulator
Chassis
Form Factor
  • 1U Rackmount
Model
  • CSE-LB16TS-R860AWP
Dimensions and Weight
Height
  • 1.7" (43 mm)
Width
  • 17.2" (437 mm)
Depth
  • 23.5" (597 mm)
Package
  • 7.7" (H) x 23.7" (W) x 31.8" (D)
Weight
  • Gross Weight: 40 lbs (18.14 kg)
  • Net Weight: 25 lbs (11.34 kg)
Available Color
  • Black
Front Panel
LED
  • Device Activity
  • LAN 1 Activity
  • LAN 2 Activity
  • Power status
  • System information
Buttons
  • Power On/Off 
  • UID button
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 2 PCIe 4.0 x16 FHHL slot(s)
    • 2 PCIe 4.0 x16 AIOM slot(s) (OCP 3.0 compatible)
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 10 bay(s)
    • 10 front hot-swap 2.5" NVMe*/SAS*/SATA drive bay(s)
  • (*NVMe/SAS support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View Drive Options
M.2
  • 2 M.2 PCIe 3.0 x2 NVMe slot(s) (M-key 2280(default); VROC required for RAID)
  • View M.2 Options
System Cooling
Fans
  • 6x 4cm heavy duty fans with optimal fan speed control
Air Shroud
  • 2 Air Shroud(s)
Power Supply
800W/860W Redundant Platinum Level Hot-plug power supplies
Note: SYS-120C-TN10R-EU (European) SKU uses PWS-861A-1R (Titanium Level)
Dimension (WxHxL)
  • 54.5 x 40.25 x 322 mm
+12V
  • Max: 66.6A / Min: 0A (100Vac-127Vac)
  • Max: 71.6A / Min: 0A (200Vdc-240Vdc)
  • Max: 71.6A / Min: 0A (200Vac-240Vac)
5V SB
  • Max: 4A / Min: 0A
AC Input
  • 800W: 100-127Vac / 50-60Hz
  • 860W: 200-240Vdc / 50-60Hz
  • 860W: 200-240Vac / 50-60Hz
Output Type
  • Backplanes (gold finger)
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 90% (Non-Condensing)
  • Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
Optional Parts List
Part Number Qty Description
3108 CacheVault BTR-CV3108-1U1 1 CacheVault for Broadcom 3108 with mount for 1U 40 cm fan slot. (Note: It will replace one fan and lower overall system cooling)
BTR-TFM8G-LSICVM02 1 CacheVault for Broadcom 3108 (requires a mount)
3108 RAID Card CBL-SAST-1260-100 1 MiniSAS HD x8 (LE) to 2x Slimline x4 (STR) 60CM
AOC-S3108L-H8IR-16DD 1 Standard LP 8 internal ports (12Gb/s) Gen-3 16HDD RAID 0, 1, 5, 6, 10, 50, 60
3808 HBA Card AOC-S3808L-L8IT 1 Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA
CBL-SAST-1276F-100 • 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
3816 HBA Card AOC-S3816L-L16IT 1 Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA
CBL-SAST-1265F-100 1 Slimline x8 (STR) to Slimline x4 (STR) 64CM
CBL-SAST-1276F-100 • 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
3908 RAID Card AOC-S3908L-H8IR-16DD 1 Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60
CBL-SAST-1276F-100 • 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
3908/3916 CacheVault BTR-CVPM05 1 CacheVault for Broadcom 3908/3916 (requires a mount)
3916 RAID Card AOC-S3916L-H16IR-32DD 1 Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60
CBL-SAST-1265F-100 1 Slimline x8 (STR) to Slimline x4 (STR) 64CM
CBL-SAST-1276F-100 • 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
AIOM Network Card(s) AOC-A25G-i4SM - OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1
AOC-A25G-m2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX
AOC-ATG-i2SM - OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2
AOC-A25G-i2SM - OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1
AOC-A25G-b2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2
AOC-A100G-b2CM - OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508
AOC-AG-i2M - OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2
AOC-AG-i4M - OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4
AOC-AG-i4SM - OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4
AOC-AH25G-m2S2TM - OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2
AOC-ATG-b2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416
AOC-ATGC-i2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2
AOC-ATG-i2T2SM - OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4
AOC-ATG-i2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2
AOC-ATG-i4SM - OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1
Cable Management Arm MCP-290-00152-0N • 1 1U Supermicro Cable Management Arm 2nd Gen
CacheVault Mount MCP-240-00127-0N 1 CacheVault mounting tray for 2.5" drive bay
MCP-240-00203-0N 1 CacheVault mounting bracket for PCIe slot
MCP-240-21747-0N 1 CacheVault mounting card for AIOM slot
Fan Upgrade FAN-0163L4 • 6 40x40x56 mm 23.3K-20.3K RPM Counter-rotating Fan
Inlet Temp Sensor MCP-280-00033-0N 1 Universal Thermal sensor kit with 80cm I2C cable
License SFT-DCMS-SINGLE • 1 Supermicro System Managment Software License
SFT-SDDC-SINGLE 1 Supermicro Data Center Monitor License
M.2 Tray AOC-SLG3-2SM2 - Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 SATA Modules RAID 0,1
AOC-SLG3-2M2 - Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules
AOC-SLG4-2H8M2 - Low Profile PCIe x8 add-on card supports 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0,1
AOC-SLG3-2NM2 - Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules RAID 0,1
NC-SI Cable CBL-PWEX-1099-34 1 FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM
NVMe Cable CBL-KIT-120C-TN10R-10 1 Enables 10 NVMe drive bays. Kit includes:
4x CBL-SAST-1219LP-85 (bay # 0-3, 6-9)
1x CBL-SAST-1234FLP-85 (bay # 4-5)
Power Supply Upgrade PWS-1K27A-1R • 2 1200W Redundant Titanium Level Power Supply
TPM AOM-TPM-9670V-S-FIPS 1 SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor
AOM-TPM-9670V 1 SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor
AOM-TPM-9672V 1 SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor
AOM-TPM-9672V-FIPS 1 SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor
VROC HW Key AOC-VROCSTNMOD 1 Intel VROC Standard RAID 0, 1, 10
AOC-VROCPREMOD 1 Intel VROC Premium RAID 0, 1, 5, 10
SYS-121H-TNR parts list

Guaranteed support from day one

We’re committed to having your back no matter the issue or time of day, starting when we first connect.

Experts on standby when needed icon

Experts on standby when needed

Get the answers you need fast with guidance from our support team.

Price match anyone icon

Price match anyone

Stay within your budget by paying the lowest, most up-to-date market prices.

Free ground shipping on everything icon

Free ground shipping on everything

Avoid paying hefty shipping fees each time you need a new product.

Lets connect

We’re more than just a tech company. We’re a motivated team of innovators, and creators. Ready to take your business to the next level?