UP SuperServer SYS-511R-W

1U WIO with 4 hot-swap 3.5″ SAS/SATA (2 NVMe hybrid) bays, up to 2 PCIe 5.0 slots and 1 PCIe 4.0 slot

Previous slide
Next slide
Intel Logo
  • Virtualization
  • Enterprise Server
  • Entry GPU server
  • Cloud Computing
  • Data Center Optimized
  • Rack Workstation
  1. Single Socket V0 (LGA-1700) supports Intel®  Xeon® E-2400 series, Intel®  Pentium® processors
  2. 4 DIMMs; Up to 128GB of DDR5 ECC UDIMM memory with speeds of up to 4400MHz
  3. 1 PCIe 5.0 x16 or 2 PCIe 5.0 x8 (FHFL);
    1 PCIe 4.0 x4 (in x16 LP)
  4. Intel® Ethernet Controller i210 2x 1GbE RJ45
  5. Default single Titanium 600W Power Supply; Optional redundant power by adding 1x Power Supply Module
Product SKUs
SuperServer SYS-511R-W
Motherboard
Super X13SCW-F
Processor
CPU
  • Single processor(s)
  • Intel® Xeon® E-2400 series Processors and 12th Gen. Pentium® Processors
Core Count
  • Up to 8C/16T; Up to 24MB Cache
Note
  • Supports up to 95W TDP CPUs (Air Cooled)
GPU
Max GPU Count
  • Up to 1 double-width or 1 single-width GPU(s)
Supported GPU
  • NVIDIA PCIe: L40, RTX A4000, RTX A2000, L4
  • View GPU Options
CPU-GPU Interconnect
  • PCIe 5.0 x16 CPU-to-GPU Interconnect
System Memory
Memory
  • Slot Count: 4 DIMM slots/2 Channels
  • Max Memory (2DPC): Up to 128GB 4400MT/s ECC DDR5 UDIMM
  • View Memory Options
Memory Voltage
  • 1.1V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1/5/10 support
Chipset
  • Intel® C266
Network Connectivity
  • 2 RJ45 1GbE with Intel® I210
  • View AOC Options
Input / Output
LAN
  • 2 RJ45 1 GbE LAN port(s)
  • 1 RJ45 1 GbE Dedicated IPMI LAN port(s) (IPMI shared on LAN port 1)
USB
  • 4 USB 2.0 port(s) (header)
  • 2 USB 2.0 Type-A port(s) (rear)
  • 2 USB 3.2 Gen1 port(s) (Header)
  • 1 USB 3.2 Gen2 Type-A port(s) (Header)
  • 2 USB 3.2 Gen2 Type-A port(s) (Rear)
Video
  • 1 VGA port(s)
Serial
  • 1 COM port(s) (Rear)
  • 1 COM port(s) (Header)
TPM
  • 1 TPM header
System BIOS
BIOS Type
  • AMI 32MB SPI Flash EEPROM
Management
Software
  • SuperCloud Composer
  • Supermicro Server Manager (SSM)
  • Supermicro Update Manager (SUM)
  • Supermicro SuperDoctor® 5 (SD5)
  • Super Diagnostics Offline (SDO)
  • Supermicro Thin-Agent Service (TAS)
  • SuperServer Automation Assistant (SAA) New!
Power configurations
  • ACPI/APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • Supply Chain Security: Remote Attestation
  • Runtime BMC Protections
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
  • 6 + 1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 1U
Model
  • CSE-815BTS-R000WNP
Dimensions and Weight
Height
  • 1.7" (43 mm)
Width
  • 17.2" (437 mm)
Depth
  • 25.6" (650 mm)
Package
  • 8.5" (H) x 23.5" (W) x 33.7" (D)
Weight
  • Gross Weight: 34.5 lbs (15.46 kg)
  • Net Weight: 21.5 lbs (9.75 kg)
Available Color
  • Black
Front Panel
LED
  • Fan Fail/System Over Heat LED
  • HDD activity LED
  • Network Activity LEDs
  • Power status LED
  • Unit Identification (UID) LED
Buttons
  • Power On/Off button
  • System Reset button
  • Unit Identification (UID) button
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 2 PCIe 5.0 x8 FHFL slot(s)
    • 1 PCIe 4.0 x4 (in x16) LP slot(s)
  • Option A
    • 1 PCIe 5.0 x16 FHFL double-width slot(s)
    • 1 PCIe 4.0 x4 (in x16) LP slot(s)
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 4 bay(s)
    • 4 front hot-swap 3.5" SAS*/SATA drive bay(s)
  • Option A: Total 4 bay(s)
    • 2 front hot-swap 3.5" PCIe 4.0 NVMe*/SAS*/SATA drive bay(s)
    • 2 front hot-swap 3.5" SAS*/SATA drive bay(s)
  • (*NVMe/SAS support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View Drive Options
M.2
  • 2 M.2 PCIe 4.0 x4 NVMe slot(s) (M-key 2280/22110)
  • View M.2 Options
Peripheral Bays
  • 2 2.5" bay(s) (optional)
System Cooling
Fans
  • 2 AOC cooling Fan(s) (optional)
  • 4 counter-rotation PWM 40x40x56mm Fan(s)
Power Supply
Operating Environment
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -30°C to 60°C (-22°F to 140°F)
  • Operating Relative Humidity: 8% to 80% (non-condensing)
  • Non-operating Relative Humidity: 8% to 90% (non-condensing)
Standard Parts (Parts Included)
  Part Number Qty Description
Motherboard / Chassis MBD-X13SCW-F

 
CSE-815BTS-R000WNP
1

 
1
Super X13SCW-F Motherboard

 
1U Chassis
Backplane BPN-NVME5-LA15-S4 1 1U 4-Slot 3.5
Cable CBL-CDAT-0674 1 4 Pin to 4 Pin I2C Cable, 30cm, 26AWG, 4 Wires, Pinout 1-1
CBL-SAST-1275A-100 1 Slimline x8 (STR) to 4x SATA, P1 75cm, P2 75cm, P3 90cm
CBL-0335L 1 FRONT CTL CABLE 20 PIN TO 20 PIN W/TUBE,70CM,PBF
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
Power Supply MCP-250-00018-0N 1 PWS dummy cover for 1U redundant power suppy w/ handle (54.5mm wide)
PWS-601A-1R 1 1U redundant 600W Titanium 54.5x40x322mm power supply
MCP-250-81502-0N 1 SC815 Redundant Power Distributor Cover
Air Shroud MCP-310-81507-0B 1 Mylar air shroud for 1U SC815B with X13SCW
MCP-310-81506-0B 1 Air block for 1U WIO SC815B with X13SEW
Manual MNL-2602-QRG 1 511R-W Quick Reference Guide
Riser Card RSC-W-68G5 1 1U LHS WIO Riser card with one PCIe 5.0 X16 and one PCIe
RSC-WR-6 1 1U RHS WIO Riser card with one PCIe 4.0 x16 slot,HF,RoHS
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0086P 1 1U Passive HS for Intel Raptor Lake (Catlow) SocketV LGA1700
*Power Distributor PDB-PT116-SL8824 1 Based on PDB-PT116-L8824 to optimize 24Pin etc cable lengths
*Fan Holder CSE-PT0135 1 FAN HOLDER FOR SIX 40X56MM COUNTER ROTATING FANS
MCP-340-00035-0B 2 Dummy fan 40x56mm for 40x56 counter-rotating fan (cost-effective)
*Peripheral Drive CSE-PT93L-B 1 Black DVD dummy cover for SC813, 813M, 815, PBF-RoHS
*Fan FAN-0163L4 4 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan
*Front Panel FPB-FP815U 1 815 UIO front control board (U)
*Drive Tray(s) MCP-220-00075-0B 4 Black gen 5.5 hot-swap 3.5" HDD tray
*Rear Window MCP-240-00202-0N 1 1U WIO rear window to support top-load riser bracket for SC815B,SC116B
*Rail Set MCP-290-00016-0N 1 1U open rack bracket set for CSE-PT51L,MCP-290-00054-0N
MCP-290-00054-0N 1set Rail set, quick/quick, optional for 1U 17.2
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
  Part Number Qty Description
3.5" to 2.5" Converter Tray(s) MCP-220-00043-0N - Hot-swap Gen-4 3.5" to 2.5" HDD tray, Black
3.5'' to 2.5" NVMe Drive Tray(s) MCP-220-00138-0B 2 Tool-less Hot-swap Gen-5.5 NVMe 3.5'' to 2.5'' drive tray, Orange tab, Black
CacheVault BTR-CVPM05 + MCP-240-00203-0N (For S3908) 1 CacheVault for Broadcom 3908 with SuperCap mounting bracket for PCIe location
BTR-CV3916-1U1 (For S3908) 1 CacheVault for Broadcom 3908 with SuperCap mounting in 1U 40x56 fan tray
Cooling Fan FAN-0163L4 2 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan
DVD-ROM / DVD-RW DVM-TEAC-DVD-SBT5 1 TEAC slim DVD-ROM SATA drive
DVM-TEAC-DVDRW-SBT5 1 PHILPS slim DVD-RW SATA drive
DVD-ROM Accessory CDM-USATA-G + 1x CBL-0470L + 1x CBL-0099 1 Slim SATA DVD mounting kit
Front Bezel CSE-PTFB-813LB 1 Black Front Bezel
CSE-PTFB-813-02B 1 Black Front Bezel w/ Round Venting Holes
Hot-swap 2.5" kit (DVD slot) MCP-220-81506-0N + 1x CBL-SAST-1270S (max 1pc) 1 Single 2.5" SAS3 (12Gb/s) hot swap in slim DVD form factor
Hot-swap 2.5" kit (FDD slot) MCP-220-81504-0N + 1x CBL-SAST-1270S (max 1pc) 1 Single 2.5" SAS3 (12Gb/s) hot swap in slim FDD form factor
Inlet Thermal Sensor MCP-280-00034-0N 1 Inlet Thermal sensor kit with 40cm I2C cable
NVMe Cable (Drive Bay 0-1) CBL-MCIO-1260M5Y 1 MCIO (x8 to 2 x4) STR,60CM,85OHM
Power Supply PWS-601A-1R 1 Optional redundant power supply
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
Storage Control Card and Cable(s) AOC-S3908L-H8iR-16DD 1 Standard LP, 8 internal ports (12Gb/s) PCIe 4.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60
Storage Control Card and Cable(s) (HBA) AOC-S3808L-L8IT 1 Standard LP, 8 internal ports (12Gb/s) PCIe 4.0 x8, 122HDD; HBA
TPM AOM-TPM-9672V 1 TPM 2.0 with 10 pins SPI support, vertical form factor
AOM-TPM-9670V 1 TPM 2.0, vertical form factor
SYS-121H-TNR parts list

Guaranteed support from day one

We’re committed to having your back no matter the issue or time of day, starting when we first connect.

Experts on standby when needed icon

Experts on standby when needed

Get the answers you need fast with guidance from our support team.

Price match anyone icon

Price match anyone

Stay within your budget by paying the lowest, most up-to-date market prices.

Free ground shipping on everything icon

Free ground shipping on everything

Avoid paying hefty shipping fees each time you need a new product.

Lets connect

We’re more than just a tech company. We’re a motivated team of innovators, and creators. Ready to take your business to the next level?